Enclosure & structure
01- DIY enclosure 1× included
- Metal 1 set
- Adjustable cell compression plates & tie-rods 1 set
DIY Battery Kits / Project Sigma
Case Kit · No Cells 57.6 V · DIY enclosure · Fits 280,304 Ah cells
Ask our engineering desk for the next intake date, or switch to an in-stock option above.
Ask about restock →Send your quantity, target inverter and delivery postcode and our engineering team will reply with a landed quote.
Request a quote →No laser welding. Pre-cut tinned copper busbars (18S layout) and metric fasteners bolt straight onto the cell studs.
Adjustable end-plates and tie-rods hold prismatic cells uniformly to limit swelling and protect cycle life.
CAN,RS485 ports are pre-wired for hybrid inverters that accept a BMS CAN or RS485 link.
Warranty terms are stated on this page and in the manual. Replacement BMS boards, screens and busbars ship separately by express air courier.
Bill of materials
Every hardware group below reflects the selections in the configurator above. Optional upgrades flip live between optional, selected and pre-order status.
Interactive engineering check
Check a real cell model (or enter custom dimensions) against this enclosure's clearance limits, pick your parallel bank size and inverter rating, and see the live pack estimate.
Checks run against the cell bay clearance, compatible capacity range, terminal style and the BMS parallel limit stored on this SKU.
Datasheet & dimensions
Every value on this page is read from the product's structured spec record — nothing here is a marketing estimate.
| Configuration | Case Kit · No Cells |
|---|---|
| Topology & nominal voltage | 18S1P · 57.6 V |
| Target pack energy | 18.09 kWh (@ 314 Ah) |
| Continuous charge / discharge | 150 A / 150 A (8.64 kW) |
| BMS platform | 18S BMU (BMU) |
| Communication interfaces | CAN,RS485 |
| Enclosure form factor | Project Sigma |
| Case material | Metal · adjustable compression |
| Packed net weight | 90 kg |
| Compatible cell capacity | 280,304 Ah |
| Required cell terminal | Single Pole |
Fastener torque values are listed in the assembly manual for this enclosure.
Closed-loop interfaces carried by this BMS:
BMS & assembly reality
We state firmware ownership plainly before you buy, and publish the stepped voltage check that prevents a fried BMS board during commissioning.
| Decision factor | HV BMU |
|---|---|
| Firmware ownership | Maintained by Gobel Power (custom firmware support) |
| Bluetooth app | No — front LCD or WiFi module |
| Interfaces | CAN,RS485 |
Mount casters or rack handles, the LCD display, the low-voltage switch and the insulated output terminals on a clean dry bench.
Line the outer walls with FR4 epoxy boards. Place cells with alternating polarity and insert an FR4 separator between every pair.
Tighten the steel compression end-plates and tie-rods evenly so the prismatic cells stay immobilised during cycling.
Fit the series copper busbars with spring and flat washers, then connect the power bars to the breaker and the BMS.
Mount the voltage sensing board and NTC probes. Measure every pin with a DC multimeter before you plug it into the BMS.
Plug in the BMS sense harness, switch on the low-voltage supply, verify the cell voltages on the LCD, connect the CAN or RS485 cable and close the DC breaker.
Black probe on B−, red probe stepping across B1 → B18. Every step must climb by one cell voltage before you connect the BMS.
• If any pin drops or jumps by more than 0.1 V, stop and re-check the busbar polarity before plugging into the BMS.
Complete your build
Pair this enclosure with batch-matched Grade A cells, add cloud telemetry, or switch to a factory-assembled battery if you would rather not pick up a wrench.
Matched cells
Grade A prismatic cells with factory capacity and IR matching, Single Pole terminals — the exact size that drops into this bay.
Cloud monitoring
Plug it into the BMS comm port for live state of charge, cell-level voltage alerts and remote diagnostics.
Prefer zero assembly?
Same cell architecture, assembled, tested and ready to connect straight out of the crate — no torque wrench required.
Global fulfilment
Steel enclosures travel in foam-lined export crates. Choose local regional stock for fast customs-cleared delivery, or Shenzhen factory direct for the lowest landed cost.
Already cleared locally for fast courier or pallet dispatch (0% EU import duty · Excl. VAT), with local support for verified quality issues.
Factory-direct DDP sea or rail freight worldwide. Replacement BMS boards, screens and busbars travel separately by express air courier in 5–7 days.
Frequently asked
Practical answers on cell fit, BMS setup, pre-order dispatch dates and warranty coverage.
No — the 3.2V LiFePO4 prismatic cells are NOT included and must be purchased separately. The kit is designed for 280Ah, 304Ah, and 314Ah prismatic cells (e.g. EVE MB31 314Ah), frequently bought together with the kit.
Everything else is included — all accessories, ready to use once connected to your inverter:
Note: the rack is not included. This all-in-one design means no hunting for matching HV components — assemble your cells, wire it up, and the pack is ready.
The GP-SRA-PC314 is built from modular 18S groups (57.6V nominal per module), so you scale the system voltage by adding modules:
Any configuration in 18S increments between 288V and 864V works, which is why this HV DIY kit fits both 300V-class and 600V-class battery banks.
Ordering: the base kit includes the BMU, HV box, and cooling; each additional battery module is priced as an option (module quantity 6–15 pcs selectable at checkout). Pair with your preferred 3.2V 280Ah–314Ah LiFePO4 cells to set the pack's kWh capacity.
High-voltage safety is engineered in, not bolted on:
Operating temperature is -20°C to +55°C. These protections make the kit suitable for professional and advanced DIY applications — residential and commercial solar ESS, EV conversions, industrial UPS and backup power, and DC fast charging stations.
The BMU communicates over CANBus and RS485, compatible with most high-voltage hybrid and off-grid inverters — the same communication classes used by Deye, GoodWe, Growatt, Solis, Luxpower and other HV-series hybrid inverters.
Unlike low-voltage 51.2V packs, HV battery systems rely on proper lithium-mode communication — we recommend confirming your inverter's HV battery protocol (CAN baud rate and battery type settings) before assembly.
Applications — the modular 288V–864V range covers:
Warranty:
Delivery:
Installers & bulk builds
Send your target kWh, inverter model and delivery postcode. Our engineering desk replies within one business day with pallet pricing and a complete wiring diagram.