SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV280H230616R1009 303.00 57.21 43.27 GP-PC200 BMS
GPRP280L231127R3201 284.00 57.41 42.26 GP-PC200 BMS
GPEV280L230523R1011 286.00 56.62 41.58 GP-PC200 BMS
GPEV280L230602R1605 303.00 57.01 40.51 GP-PC200 BMS
GPEV280L230602R2008 286.00 57.01 40.54 GP-PC200 BMS
GPEV280H240124R1005 300.00 58.00 42.08 GP-PC200 BMS
GPEV280L230801R3303 288.00 56.76 42.10 GP-PC200 BMS
GPHC280H240506R1012 294.00 57.26 41.20 GP-PC200 BMS
GPEV280H231220R1024 298.00 57.99 43.57 GP-PC200 BMS
GPEV280H230705R1003 305.00 57.97 41.11 GP-PC200 BMS
GPEV306H240514R1004 329.00 56.81 41.42 GP-JK200 BMS
GPEV280H240401R1024 304.00 57.99 43.72 GP-RN200 BMS
GPEV280L230602R1006 298.00 57.01 43.08 GP-PC200 BMS
GPEV280L230801R3401 287.00 56.31 41.99 GP-PC200 BMS
GPEV280L230801R2404 289.00 57.16 40.96 GP-PC200 BMS
GPHC280H240401R1001 294.00 56.75 42.91 GP-JK200 BMS
GPEV280H230625R1010 306.00 57.65 41.40 GP-PC200 BMS
GPRP280L231127R3202 284.00 57.99 41.22 GP-PC200 BMS
GPEV304L230926R3001 312.00 57.77 41.24 GP-PC200 BMS
GPEV280H230625R1006 305.00 57.58 40.63 GP-PC200 BMS
Specification of The Battery

Pack SN:GPEV280H230625R1017
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: GP-PC200 BMS
Balancer Type: 5A Active Balancer
Heater: Without Heater
Cell Type: EVE LF280K
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 306.00 Ah (15.67 kWh)
Max Charge Voltage: 57.71 V
Min Discharge Voltage: 40.47 V
Charge Test Method
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Method
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) OCV2 (mV) OCV3 (mV) RI1 (mΩ) RI2 (mΩ) RI3 (mΩ) Thick (mm) Test Date
1 65 04QCB76G55703JD5G0001683 314.55 2,797.6 2,789.1 3,297.6 0.1576 0.1556 0.1574 71.49 2023-06-08
2 70 04QCB76G41203JD5G0000935 314.54 2,805.8 2,797.5 3,297.8 0.1525 0.1510 0.1498 71.43 2023-06-09
3 122 04QCB76G59403JD5H0002702 314.54 2,803.0 2,797.8 3,297.4 0.1548 0.1546 0.1580 71.54 2023-06-08
4 141 04QCB76G55503JD5G0004648 314.57 2,800.6 2,794.8 3,297.5 0.1537 0.1530 0.1563 71.50 2023-06-08
5 175 04QCB76G41203JD5H0010804 314.55 2,800.9 2,797.4 3,297.6 0.1529 0.1520 0.1570 71.58 2023-06-08
6 188 04QCB76G55703JD5G0001456 314.57 2,804.8 2,796.1 3,297.4 0.1560 0.1554 0.1570 71.50 2023-06-08
7 194 04QCB76G55703JD5G0004990 314.56 2,798.2 2,792.3 3,297.6 0.1552 0.1547 0.1579 71.50 2023-06-08
8 225 04QCB76G41203JD5H0009251 314.54 2,794.0 2,786.5 3,297.4 0.1505 0.1551 0.1561 71.70 2023-06-08
9 255 04QCB76G64503JD5G0000176 314.59 2,799.5 2,793.6 3,297.3 0.1519 0.1545 0.1541 71.67 2023-06-08
10 259 04QCB76G52503JD5F0003464 314.56 2,800.0 2,791.4 3,297.5 0.1555 0.1559 0.1568 71.67 2023-06-08
11 314 04QCB76G41203JD5G0001679 314.53 2,804.3 2,798.8 3,297.6 0.1555 0.1537 0.1569 71.43 2023-06-08
12 420 04QCB76G41103JD5F0000673 314.54 2,807.1 2,801.5 3,297.3 0.1543 0.1526 0.1487 71.57 2023-06-09
13 490 04QCB76G41203JD5G0000889 314.59 2,805.1 2,796.1 3,297.6 0.1535 0.1557 0.1487 71.42 2023-06-09
14 493 04QCB76G55503JD5G0004911 314.58 2,799.1 2,790.6 3,297.7 0.1545 0.1533 0.1504 71.55 2023-06-09
15 560 04QCB76G41203JD5H0010103 314.55 2,783.8 2,777.8 3,297.2 0.1530 0.1545 0.1546 71.47 2023-06-08
16 590 04QCB76G52503JD5F0003633 314.59 2,798.4 2,789.8 3,297.8 0.1561 0.1564 0.1501 71.47 2023-06-09
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.