Flash Sale For USA DiySolarForum Users! >> Click to Check >>

Battery Pack Information Lookup

Get Data of Your Gobel Power Battery
Decode
GP-SR1-PC200 Premium Example: GPEV280H231204R1010
GP-SR1-PC200 Standard Example: GPHC280H240401R1003
GP-LA12-280AH Standard Example: GDHC280H240312R1401
More Examples
SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV280L230801R2401 288.00 56.84 40.37 GP-PC200 BMS
GPRP280L231127R2904 285.00 57.66 43.70 GP-PC200 BMS
GPEV280L230913R2924 288.00 57.87 40.04 GP-PC200 BMS
GPHC280H240427R1201 295.00 57.45 40.75 GP-PC200 BMS
GPEV280H240505R1009 307.00 58.00 40.89 GP-PC200 BMS
GPEV280L230801R2203 287.00 57.52 40.46 GP-RN150 BMS
GPEV280H231030R1006 301.00 57.62 41.39 GP-PC200 BMS
GPEV280H240122R1010 301.00 57.99 41.70 GP-PC200 BMS
GPEV280H230911R1001 299.00 56.75 42.18 GP-PC200 BMS
GPHC280H240401R1003 295.00 57.17 40.42 GP-PC200 BMS
GPHC280H240506R2903 294.00 56.56 41.11 GP-PC200 BMS
GPEV280H240105R1033 301.00 58.00 43.15 GP-PC200 BMS
GPEV280L230602R1605 303.00 57.01 40.51 GP-PC200 BMS
GPEV280H231220R1024 298.00 57.99 43.57 GP-PC200 BMS
GPEV280H230625R1038 308.00 57.71 40.89 GP-PC200 BMS
GPEV280H231030R1013 294.00 56.03 43.58 GP-PC200 BMS
GPHC280H240413R1005 293.00 56.66 41.08 GP-PC200 BMS
GPEV280H240507R1021 300.00 57.91 42.86 GP-PC200 BMS
GPEV280H240105R1016 301.00 58.00 42.92 GP-PC200 BMS
GPEV280L230913R2918 286.00 56.84 40.74 GP-PC200 BMS
Specification of The Battery

Pack SN:GPEV280H230705R1020
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: GP-PC200 BMS
Balancer Type: 5A Active Balancer
Heater: Without Heater
Cell Type: EVE LF280K
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 304.00 Ah (15.56 kWh)
Max Charge Voltage: 56.86 V
Min Discharge Voltage: 41.04 V
Charge Test Method
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Method
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) OCV2 (mV) OCV3 (mV) RI1 (mΩ) RI2 (mΩ) RI3 (mΩ) Thick (mm) Test Date
1 17 04QCB76G41103JD5F0000676 315.38 2,804.3 2,799.8 3,297.4 0.1507 0.1507 0.1517 71.81 2023-06-08
2 95 04QCB76G45203JD5G0001929 315.38 2,803.2 2,797.2 3,297.4 0.1501 0.1520 0.1536 71.45 2023-06-08
3 104 04QCB76G40703JD5D0000665 315.34 2,805.9 2,793.9 3,297.4 0.1538 0.1558 0.1548 71.51 2023-06-08
4 149 04QCB76G55703JD5G0002828 315.34 2,799.5 2,792.7 3,297.6 0.1514 0.1551 0.1550 71.50 2023-06-08
5 151 04QCB76G41103JD5G0009822 315.34 2,804.9 2,799.1 3,297.3 0.1476 0.1490 0.1517 71.43 2023-06-08
6 153 04QCB76G55703JD5G0000834 315.33 2,801.5 2,792.5 3,297.5 0.1558 0.1544 0.1564 71.48 2023-06-08
7 155 04QCB76G69903JD5G0000219 315.35 2,805.4 2,799.3 3,297.6 0.1523 0.1520 0.1545 71.52 2023-06-08
8 167 04QCB76G41103JD5F0000663 315.36 2,802.8 2,797.0 3,297.4 0.1487 0.1492 0.1512 71.62 2023-06-08
9 216 04QCB76G55503JD5G0003735 315.41 2,803.7 2,797.9 3,297.4 0.1530 0.1541 0.1546 71.57 2023-06-08
10 251 04QCB76G55703JD5G0000158 315.36 2,798.4 2,791.8 3,297.5 0.1557 0.1542 0.1581 71.50 2023-06-08
11 258 04QCB76G41103JD5F0001661 315.36 2,804.9 2,796.5 3,297.3 0.1501 0.1512 0.1541 71.46 2023-06-08
12 305 04QCB76G55503JD5G0004992 315.40 2,794.5 2,784.7 3,297.7 0.1554 0.1548 0.1576 71.50 2023-06-08
13 322 04QCB76G52203JD5F0001911 315.41 2,805.1 2,798.4 3,297.1 0.1558 0.1571 0.1570 71.82 2023-06-08
14 334 04QCB76G41203JD5G0001766 315.41 2,804.1 2,797.6 3,297.4 0.1525 0.1549 0.1534 71.43 2023-06-08
15 398 04QCB76G40703JD5D0002183 315.33 2,802.3 2,790.6 3,297.5 0.1542 0.1549 0.1576 71.52 2023-06-08
16 417 04QCB76G40703JD5D0003709 315.38 2,801.9 2,790.2 3,297.3 0.1576 0.1569 0.1586 71.44 2023-06-08
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.

Home >>  Battery Pack Information Lookup