SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPRP280L240102R3204 283.00 57.77 42.74 GP-PC200 BMS
GPEV280H230616R1024 301.00 57.09 42.54 GP-PC200 BMS
GPEV280H240122R1003 298.00 58.00 42.89 GP-PC200 BMS
GPEV280H240323R1012 302.00 57.99 41.92 GP-PC200 BMS
GPRP280L231115R1901 291.00 57.88 40.80 GP-PC200 BMS
GPEV280H230705R1005 303.00 57.01 41.52 GP-PC200 BMS
GPEV280H230625R1036 307.00 57.53 40.40 GP-PC200 BMS
GPRP280L231207R3504 284.00 57.57 41.12 GP-PC200 BMS
GPEV280H231019R1031 302.00 58.00 41.53 GP-PC200 BMS
GPRP280L231012R1014 289.00 57.70 40.26 GP-PC200 BMS
GPRP280L231012R1009 292.00 57.74 40.02 GP-PC200 BMS
GPHC280H240422R1002 293.00 56.71 42.84 Unknown
GPEV280H240401R1021 305.00 57.99 43.99 Unknown
GPHC280H240418R1003 293.00 57.08 43.51 Unknown
GPEV280L230801R2204 287.00 57.39 40.15 GP-PC200 BMS
GPHC280H240413R1203 295.00 57.19 40.96 GP-PC200 BMS
GPRP280L240102R1902 288.00 57.99 42.41 GP-PC200 BMS
GPEV280H240129R1005 299.00 57.99 43.45 GP-PC200 BMS
GPEV280H240323R1015 301.00 57.82 41.36 GP-PC200 BMS
GPEV280H230625R1018 306.00 57.88 40.92 GP-PC200 BMS
Specification of The Battery

Pack SN:GPHC280H240321R2902
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Standard
BMS Type: GP-PC200 BMS
Balancer Type: 4A Bluetooth Active Balancer
Heater: With Heater
Cell Type: Hithium 280
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 296.00 Ah (15.16 kWh)
Max Charge Voltage: 57.25 V
Min Discharge Voltage: 41.21 V
Charge Test Method
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Method
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Charge/Discharge Curve
(Based on GPHC280H240321R2902 Test Data)

Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) RI1 (mΩ) Self Discharge Thick (mm) Test Date
1 1 0IJCBA0B471111DCK0007882 301.63 3,284.3 0.1715 0.0208 71.70 2023-12-21
2 67 0IJCBA0B111111DCK0023411 301.17 3,284.2 0.1724 0.0231 71.69 2023-12-21
3 71 0IJCBA0B111111DCK0023388 301.36 3,284.4 0.1712 0.0242 71.69 2023-12-21
4 77 0IJCBA0B471111DCK0007754 301.13 3,284.6 0.1726 0.0229 71.71 2023-12-21
5 99 0IJCBA0B051111DCH0002792 301.27 3,284.5 0.1724 0.0228 71.73 2023-12-22
6 109 0IJCBA0B471111DCK0006189 300.69 3,283.4 0.1683 0.0203 71.70 2023-12-21
7 116 0IJCBA0B471111DCK0004337 300.84 3,284.4 0.1731 0.0242 71.70 2023-12-21
8 131 0IJCBA0B471111DCK0004303 300.92 3,284.5 0.1714 0.0232 71.90 2023-12-21
9 149 0IJCBA0B471111DCK0005881 300.70 3,283.8 0.1719 0.0250 71.68 2023-12-21
10 187 0IJCBA0B051111DCH0002433 301.20 3,284.5 0.1718 0.0228 71.78 2023-12-22
11 190 0IJCBA0B471111DCK0007701 300.88 3,284.6 0.1721 0.0228 71.87 2023-12-22
12 195 0IJCBA0B051111DCH0002422 301.89 3,284.2 0.1688 0.0230 71.68 2023-12-22
13 197 0IJCBA0B051111DCG0022316 301.78 3,284.8 0.1736 0.0225 71.62 2023-12-22
14 205 0IJCBA0B051111DCH0002803 301.08 3,284.5 0.1731 0.0226 71.63 2023-12-22
15 213 0IJCBA0B471111DCK0007699 300.77 3,284.4 0.1722 0.0235 71.67 2023-12-22
16 232 0IJCBA0B471111DCL0028197 300.10 3,284.5 0.1697 0.0199 71.63 2023-12-22
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.

Home >>  Battery Pack Information Lookup