Your No.1 Choice for High-Quality Batteries.

Home

Contact Us

Downloads

Reseller Login

Aftersale&Forum

Battery Pack Information Lookup

Get Data of Your Gobel Power Battery
Decode
GP-SR1-PC314 Premium Example: GPEV314H240921R1012
GP-SR1-JK314 Standard Example: GPEV314M250109R1001
GP-SR1-JK314 Standard Example: GPGT314L250510R1011
GP-SR1-JK314 Standard Example: GPBT314M250926R1003
GP-SR1-JK314 Standard Example: GPCN314M250929R1003
GP-SR3-PC100 Example: GPEV100H240930R1003
GP-LA12-280AH Premium Example: GDEV280H240307R1008
GP-LA12-280AH Standard Example: GDHC280H240312R1401
More Examples
SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV314H251022R1015 327.00 57.87 41.64 GP-PC200B BMS
GPEV314H250520R1001 331.00 57.97 41.68 GP-PC200 BMS
GPEV314H241015R1024 322.00 57.98 42.43 GP-PC200 BMS
GPHC280H240413R1004 294.00 56.63 41.47 GP-PC200 BMS
GPLS280M251201R2905 285.00 57.08 42.58 GP-PC200B BMS
GPEV314H250507R1012 329.00 57.85 41.29 GP-PC200 BMS
GPEV280H240921R1013 307.00 57.45 41.55 GP-PC200 BMS
GPHC280H241010R1004 293.00 56.94 41.02 GP-PC200 BMS
GPEV280H240505R1004 308.00 58.00 41.60 GP-PC200 BMS
GPBT314M250926R1002 326.00 58.01 43.29 GP-JK200 BMS
GPEV314H240921R1013 326.00 57.97 41.11 GP-PC200 BMS
GPHC280H240613R1001 294.00 56.89 41.23 GP-PC200 BMS
GPEV280H230625R1026 306.00 57.38 40.59 GP-PC200 BMS
GPHC280H240515R2901 295.00 57.73 42.37 GP-PC200 BMS
GPHC280H240930R1202 292.00 56.96 41.21 GP-JK200 BMS
GPEV280H240105R1033 301.00 58.00 43.15 GP-PC200 BMS
GPEV280L230602R2004 303.00 57.01 40.81 GP-PC200 BMS
GPEV280H240905R1021 306.00 57.94 42.23 GP-RN200 BMS
GPHC280H240822R2902 294.00 57.09 42.18 GP-JK200 BMS
GPHC280M250424R1002 296.00 56.52 40.73 GP-PC200 BMS
Specification of The Battery

Pack SN:GPGT102H251017R1002
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: JK100 BMS
Balancer: Built-in BMS 2A
Heater: Without Heater
Cell Type: Gotion 102Ah
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 101.00 Ah (5.17 kWh)
Max Charge Voltage: 58.00 V
Min Discharge Voltage: 43.64 V
Charge Test Steps
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Steps
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Charge/Discharge Curve
(Based on GPGT102H251017R1002 Test Data)

Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) RI1 (mΩ) Thick (mm) Test Date
1 7 03HCB0160000AUF7W0300208 104.56 3,233.3 0.3131 49.71 2025-08-12
2 79 03HCB0160000AUF7Y1201352 106.05 3,241.2 0.3167 49.71 2025-08-16
3 94 03HCB0160000AUF700400726 104.73 3,241.1 0.3199 49.76 2025-08-16
4 101 03HCB0160000AUF700300254 104.21 3,241.5 0.3231 49.84 2025-08-16
5 107 03HCB0160000AUF7W0303816 105.57 3,234.8 0.3155 49.72 2025-08-12
6 110 03HCB0160000AUF700400278 104.93 3,241.1 0.3241 49.72 2025-08-16
7 111 03HCB0160000AUF700300548 105.61 3,241.7 0.3247 50.12 2025-08-16
8 121 03HCB0160000AUF700400270 104.77 3,241.2 0.3145 49.76 2025-08-16
9 122 03HCB0160000AUF700400318 104.82 3,241.3 0.3225 49.93 2025-08-16
10 124 03HCB0160000AUF700301287 105.87 3,241.0 0.3244 49.90 2025-08-16
11 125 03HCB0160000AUF700400521 105.26 3,241.2 0.3192 49.75 2025-08-16
12 137 03HCB0160000AUF700400527 104.56 3,241.4 0.3183 49.76 2025-08-16
13 139 03HCB0160000AUF700401315 104.76 3,241.0 0.3265 49.90 2025-08-16
14 141 03HCB0160000AUF700400942 105.38 3,241.0 0.3214 49.78 2025-08-16
15 152 03HCB0160000AUF700301293 105.71 3,241.0 0.3210 50.09 2025-08-16
16 155 03HCB0160000AUF700301533 105.12 3,241.1 0.3214 50.02 2025-08-16
Interest in our Products? Submit a Form and Get a Quote Get Quote
Why Max Charge Voltage and Min Discharge Voltage Matter

For LiFePO₄ batteries, Max Charge Voltage and Min Discharge Voltage are not just technical data — they reflect the consistency and balance of every single cell inside the pack.

When all cells reach the charging and discharging limits almost at the same time, it shows that the pack is perfectly matched, with highly uniform voltage and internal resistance. This means better efficiency, higher usable capacity, and a much longer lifespan.

At our factory, every battery pack is tested individually, and its Max Charge Voltage and Min Discharge Voltage results are published on our website for full transparency.

Most manufacturers do not share such detailed data — but we do, because we believe:

-- Real quality can be proven with real numbers

Home >>  Battery Pack Information Lookup
AI Chatbot