Flash Sale For USA DiySolarForum Users! >> Click to Check >>

Battery Pack Information Lookup

Get Data of Your Gobel Power Battery
Decode
GP-SR1-PC200 Premium Example: GPEV280H231204R1010
GP-SR1-PC200 Standard Example: GPHC280H240401R1003
GP-LA12-280AH Standard Example: GDHC280H240312R1401
More Examples
SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV280H230625R1013 307.00 57.39 40.50 GP-PC200 BMS
GPEV280H240314R1002 303.00 58.00 43.95 Unknown
GPEV280H231019R1018 301.00 58.00 41.09 GP-PC200 BMS
GPEV280H230625R1008 304.00 57.28 41.32 GP-PC200 BMS
GPEV280H231019R1027 300.00 57.74 41.52 GP-PC200 BMS
GPEV280H231019R1028 300.00 57.87 41.35 GP-PC200 BMS
GPEV280H230616R1002 303.00 57.74 42.10 GP-PC200 BMS
GPEV280H240122R1010 301.00 57.99 41.70 GP-PC200 BMS
GPEV280H240314R1014 305.00 58.00 41.86 GP-PC200 BMS
GPEV280H230616R1018 302.00 56.92 42.36 GP-PC200 BMS
GPEV280H231019R1029 291.00 56.12 45.18 GP-PC200 BMS
GPEV280H231204R1001 298.00 57.94 42.76 GP-PC200 BMS
GPEV280L230913R2926 286.00 56.52 42.15 GP-PC200 BMS
GPEV280H230625R1032 305.00 57.60 40.62 GP-PC200 BMS
GPRP280L231012R1305 290.00 57.70 40.11 GP-PC200 BMS
GPEV280L230602R1605 303.00 57.01 40.51 GP-PC200 BMS
GPRP280L231113R1703 288.00 57.64 40.70 GP-PC200 BMS
GPHC280H240506R1006 294.00 57.09 42.14 GP-PC200 BMS
GPEV280H230616R1019 301.00 56.68 41.75 GP-PC200 BMS
GPHC280H240321R1005 295.00 57.30 41.19 GP-PC200 BMS
Specification of The Battery

Pack SN:GPEV280H240314R1006
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: RN200
Balancer Type: 4A Bluetooth Active Balancer
Heater: Without Heater
Cell Type: EVE LF280K
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 299.00 Ah (15.31 kWh)
Max Charge Voltage: 58.00 V
Min Discharge Voltage: 44.27 V
Charge Test Method
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Method
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Charge/Discharge Curve
(Based on GPEV280H240314R1006 Test Data)

Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) OCV2 (mV) OCV3 (mV) RI1 (mΩ) RI2 (mΩ) RI3 (mΩ) Thick (mm) Test Date
1 12 04QCB76G53103JE180003737 312.34 2,795.8 2,791.2 3,295.9 0.1540 0.1558 0.1574 71.53 2024-03-09
2 51 04QCB76G63003JE180008770 312.32 2,796.1 2,791.4 3,296.0 0.1524 0.1525 0.1511 71.43 2024-03-09
3 80 04QCB76G42003JE180008589 312.32 2,793.3 2,787.0 3,295.9 0.1544 0.1560 0.1564 71.62 2024-03-09
4 114 04QCB76G42003JE180008912 312.33 2,796.1 2,789.7 3,295.9 0.1537 0.1543 0.1544 71.55 2024-03-09
5 134 04QCB76G42003JE180009293 312.31 2,796.4 2,790.1 3,296.0 0.1499 0.1533 0.1561 71.62 2024-03-09
6 137 04QCB76G63003JE180009100 312.34 2,795.7 2,791.2 3,296.1 0.1540 0.1543 0.1567 71.42 2024-03-09
7 146 04QCB76G63003JE180008672 312.31 2,796.4 2,791.3 3,296.1 0.1551 0.1553 0.1546 71.42 2024-03-09
8 150 04QCB76G63003JE180009154 312.30 2,796.2 2,792.1 3,296.0 0.1532 0.1546 0.1564 71.49 2024-03-09
9 158 04QCB76G63003JE180009312 312.30 2,793.5 2,789.2 3,296.0 0.1536 0.1553 0.1576 71.47 2024-03-09
10 163 04QCB76G63003JE180008658 312.35 2,797.0 2,792.1 3,296.2 0.1518 0.1546 0.1530 71.48 2024-03-09
11 212 04QCB76G53103JE180003384 312.33 2,794.5 2,789.6 3,296.0 0.1550 0.1573 0.1556 71.62 2024-03-09
12 215 04QCB76G53103JE180003561 312.30 2,796.5 2,791.1 3,296.1 0.1525 0.1547 0.1535 71.55 2024-03-09
13 259 04QCB76G63003JE180009490 312.32 2,794.0 2,789.5 3,296.1 0.1538 0.1546 0.1540 71.42 2024-03-09
14 267 04QCB76G42003JE180008910 312.36 2,793.6 2,787.3 3,295.8 0.1542 0.1554 0.1549 71.58 2024-03-09
15 291 04QCB76G53103JE180003146 312.31 2,795.5 2,790.6 3,295.9 0.1549 0.1558 0.1554 71.56 2024-03-09
16 303 04QCB76G53103JE180003759 312.32 2,795.0 2,790.6 3,295.9 0.1561 0.1566 0.1574 71.52 2024-03-09
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.