Flash Sale For USA DiySolarForum Users! >> Click to Check >>

Battery Pack Information Lookup

Get Data of Your Gobel Power Battery
Decode
GP-SR1-PC200 Premium Example: GPEV280H231204R1010
GP-SR1-PC200 Standard Example: GPHC280H240401R1003
GP-LA12-280AH Standard Example: GDHC280H240312R1401
More Examples
SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV280H231220R1006 296.00 58.00 42.13 GP-PC200 BMS
GPEV280L230801R2214 289.00 57.41 40.43 GP-PC200 BMS
GPEV280H230625R1003 305.00 57.40 41.63 GP-PC200 BMS
GPEV280H231019R1016 301.00 57.86 40.86 GP-PC200 BMS
GPEV280H230705R1006 303.00 57.11 41.62 GP-PC200 BMS
GPHC280H240321R1005 295.00 57.30 41.19 GP-PC200 BMS
GPEV280L230523R2001 297.00 57.02 41.97 GP-PC200 BMS
GPEV280H240314R1011 300.00 57.99 43.73 GP-RN200 BMS
GPRP280L231012R1304 290.00 57.91 40.24 GP-PC200 BMS
GPRP280L240102R3204 283.00 57.77 42.74 GP-PC200 BMS
GPEV280H230911R1001 299.00 56.75 42.18 GP-PC200 BMS
GPEV280H240129R1005 299.00 57.99 43.45 GP-PC200 BMS
GPEV280L230801R2101 287.00 57.69 40.01 GP-PC200 BMS
GPEV280H231227R1008 302.00 58.00 42.12 GP-PC200 BMS
GPEV280H240505R1006 305.00 57.99 41.94 GP-PC200 BMS
GPEV280L230801R2208 289.00 57.52 40.14 GP-PC200 BMS
GPHC280H240506R1004 293.00 56.24 41.44 GP-PC200 BMS
GPRP280L240304R1501 291.00 57.99 41.69 GP-PC200 BMS
GPEV280H231204R1003 303.00 58.00 43.42 GP-PC200 BMS
GPEV280H230616R1004 303.00 56.58 40.79 GP-PC200 BMS
Specification of The Battery

Pack SN:GPEV280H231010R1002
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: GP-PC200 BMS
Balancer Type: 4A Bluetooth Active Balancer
Heater: Without Heater
Cell Type: EVE LF280K
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 298.00 Ah (15.26 kWh)
Max Charge Voltage: 56.29 V
Min Discharge Voltage: 42.52 V
Charge Test Method
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Method
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) OCV2 (mV) OCV3 (mV) RI1 (mΩ) RI2 (mΩ) RI3 (mΩ) Thick (mm) Test Date
1 2 04QCB76G55703JD5G0000419 314.70 2,797.6 2,789.7 3,297.5 0.1562 0.1556 0.1570 71.52 2023-06-08
2 6 04QCB76G41203JD5H0006017 314.83 2,812.6 2,806.9 3,297.1 0.1545 0.1563 0.1552 71.52 2023-06-08
3 7 04QCB76G55503JD5G0002869 314.73 2,798.9 2,790.3 3,297.3 0.1551 0.1551 0.1550 71.49 2023-06-08
4 13 04QCB76G41203JD5G0003604 314.79 2,804.7 2,798.2 3,297.3 0.1518 0.1537 0.1555 71.47 2023-06-08
5 15 04QCB76G41203JD5G0003608 315.33 2,804.9 2,798.3 3,297.1 0.1521 0.1529 0.1538 71.45 2023-06-08
6 18 04QCB76G55503JD5G0002865 314.84 2,798.6 2,789.9 3,297.3 0.1594 0.1596 0.1572 71.49 2023-06-08
7 21 04QCB76G55503JD5G0002334 314.90 2,802.0 2,793.3 3,297.1 0.1570 0.1568 0.1574 71.50 2023-06-08
8 24 04QCB76G41203JD5G0001680 315.16 2,808.4 2,802.6 3,297.6 0.1525 0.1528 0.1547 71.43 2023-06-08
9 27 04QCB76G55703JD5G0002627 315.09 2,797.2 2,792.2 3,297.5 0.1519 0.1534 0.1569 71.48 2023-06-08
10 30 04QCB76G41203JD5G0003561 315.05 2,805.4 2,798.9 3,297.3 0.1524 0.1554 0.1564 71.47 2023-06-08
11 33 04QCB76G69903JD5H0000016 315.14 2,801.6 2,796.3 3,297.5 0.1505 0.1532 0.1565 71.49 2023-06-08
12 38 04QCB76G55503JD5G0003794 315.25 2,798.6 2,790.9 3,297.4 0.1534 0.1537 0.1557 71.49 2023-06-08
13 39 04QCB76G41203JD5G0005036 315.30 2,801.7 2,795.0 3,297.5 0.1548 0.1545 0.1567 71.44 2023-06-08
14 41 04QCB76G41203JD5H0007350 315.22 2,803.1 2,796.7 3,297.2 0.1553 0.1575 0.1569 71.50 2023-06-08
15 42 04QCB76G55503JD5G0003795 315.19 2,801.1 2,793.1 3,297.3 0.1560 0.1556 0.1571 71.60 2023-06-08
16 48 04QCB76G55503JD5G0003799 315.12 2,797.6 2,789.9 3,297.5 0.1549 0.1534 0.1551 71.51 2023-06-08
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.

Home >>  Battery Pack Information Lookup