Flash Sale For USA DiySolarForum Users! >> Click to Check >>

Battery Pack Information Lookup

Get Data of Your Gobel Power Battery
Decode
GP-SR1-PC200 Premium Example: GPEV280H231204R1010
GP-SR1-PC200 Standard Example: GPHC280H240401R1003
GP-LA12-280AH Standard Example: GDHC280H240312R1401
More Examples
SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV280H240507R1010 301.00 57.99 40.76 GP-PC200 BMS
GPEV280H230616R1022 301.00 57.52 42.65 GP-PC200 BMS
GPEV280H231204R1008 301.00 58.00 41.94 GP-PC200 BMS
GPEV280L230913R2910 283.00 57.13 41.67 GP-RN150 BMS
GPEV280H230625R1031 305.00 57.59 41.61 GP-PC200 BMS
GPHC280H240506R1401 294.00 57.30 41.44 GP-PC200 BMS
GPEV280H240314R1008 303.00 58.00 44.33 GP-RN200 BMS
GPEV280H240323R1004 302.00 58.00 42.48 GP-PC200 BMS
GPEV280H230705R1021 306.00 57.52 40.78 GP-PC200 BMS
GPRP280L231012R1013 290.00 57.46 40.00 GP-PC200 BMS
GPRP280L231212R2202 283.00 57.60 41.72 GP-PC200 BMS
GPEV280H230625R1030 306.00 57.35 41.06 GP-PC200 BMS
GPEV280L230711R3201 303.00 56.79 42.53 GP-PC200 BMS
GPEV280L230711R2001 299.00 56.98 41.85 GP-PC200 BMS
GPHC280H240422R1403 294.00 57.00 41.35 GP-PC200 BMS
GPHC280H240321R2901 295.00 57.12 41.08 GP-PC200 BMS
GPRP280L231012R1005 292.00 57.61 40.27 GP-PC200 BMS
GPEV280H240112R1012 299.00 58.00 42.15 GP-PC200 BMS
GPEV280H240401R1021 305.00 57.99 43.99 GP-RN200 BMS
GPEV280L230523R1005 283.00 56.80 40.52 GP-PC200 BMS
Specification of The Battery

Pack SN:GPEV280H230616R1022
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: GP-PC200 BMS
Balancer Type: 5A Active Balancer
Heater: Without Heater
Cell Type: EVE LF280K
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 301.00 Ah (15.41 kWh)
Max Charge Voltage: 57.52 V
Min Discharge Voltage: 42.65 V
Charge Test Method
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Method
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) OCV2 (mV) OCV3 (mV) RI1 (mΩ) RI2 (mΩ) RI3 (mΩ) Thick (mm) Test Date
1 20 04QCB76G44303JD5C0000107 315.39 2,804.4 2,795.7 3,297.4 0.1529 0.1513 0.1533 71.53 2023-06-09
2 76 04QCB76G55503JD5G0003920 315.36 2,802.2 2,794.2 3,297.7 0.1546 0.1538 0.1536 71.56 2023-06-09
3 158 04QCB76G41103JD5F0000678 315.37 2,807.0 2,801.2 3,297.3 0.1502 0.1511 0.1521 71.64 2023-06-08
4 163 04QCB76G44303JD5D0006270 315.40 2,802.2 2,795.0 3,297.4 0.1562 0.1562 0.1565 71.43 2023-06-09
5 167 04QCB76G40703JD5D0003090 315.38 2,804.8 2,795.7 3,297.8 0.1518 0.1528 0.1543 71.44 2023-06-09
6 179 04QCB76G44303JD5D0008834 315.40 2,804.3 2,794.4 3,298.0 0.1525 0.1530 0.1528 71.41 2023-06-09
7 189 04QCB76G40703JD5D0003837 315.36 2,801.8 2,791.8 3,297.5 0.1543 0.1554 0.1549 71.41 2023-06-09
8 196 04QCB76G44303JD5D0006316 315.38 2,799.2 2,789.6 3,297.7 0.1534 0.1546 0.1550 71.49 2023-06-09
9 210 04QCB76G44303JD5D0007206 315.38 2,809.4 2,803.9 3,297.6 0.1524 0.1550 0.1541 71.44 2023-06-09
10 219 04QCB76G44303JD5C0003482 315.40 2,796.3 2,790.6 3,297.6 0.1535 0.1554 0.1561 71.51 2023-06-09
11 230 04QCB76G40703JD5E0009044 315.37 2,802.2 2,794.4 3,297.5 0.1548 0.1555 0.1562 71.48 2023-06-09
12 276 04QCB76G41103JD5G0005700 315.36 2,807.3 2,800.6 3,297.6 0.1539 0.1546 0.1557 71.43 2023-06-09
13 301 04QCB76G44303JD5D0008814 315.37 2,805.5 2,795.3 3,297.7 0.1521 0.1534 0.1531 71.42 2023-06-09
14 327 04QCB76G40703JD5E0005664 315.37 2,806.5 2,799.4 3,297.4 0.1534 0.1543 0.1543 71.46 2023-06-09
15 344 04QCB76G44303JD5C0003825 315.40 2,800.9 2,791.0 3,297.4 0.1526 0.1515 0.1551 71.39 2023-06-09
16 378 04QCB76G44303JD5C0003818 315.36 2,799.9 2,789.5 3,297.4 0.1532 0.1518 0.1546 71.62 2023-06-09
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.

Home >>  Battery Pack Information Lookup