Flash Sale For USA DiySolarForum Users! >>

Battery Pack Information Lookup

Get Data of Your Gobel Power Battery
Decode
GP-SR1-PC200 Premium Example: GPEV280H231204R1010
GP-SR1-PC200 Standard Example: GPHC280H240401R1003
GP-LA12-280AH Standard Example: GDHC280H240312R1401
More Examples
SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV280H230625R1013 307.00 57.39 40.50 GP-PC200 BMS
GPEV280L230711R3202 301.00 56.83 42.41 GP-RN150 BMS
GPEV280H231019R1012 299.00 57.73 43.39 GP-PC200 BMS
GPEV280H231009R1008 298.00 57.84 41.52 GP-PC200 BMS
GPEV280H231019R1010 301.00 57.67 41.67 GP-PC200 BMS
GPEV280H240314R1011 300.00 57.99 43.73 Unknown
GPEV280H231227R1005 299.00 57.99 42.81 GP-PC200 BMS
GPEV280L230801R2214 289.00 57.41 40.43 GP-PC200 BMS
GPEV280H230705R1022 306.00 57.45 40.84 GP-PC200 BMS
GPEV280H231220R1021 295.00 58.00 43.37 GP-PC200 BMS
GPEV280H230616R1023 304.00 57.62 41.67 GP-PC200 BMS
GPEV280H240115R1004 303.00 58.00 41.93 GP-PC200 BMS
GPEV280H231123R1016 299.00 57.88 42.27 GP-PC200 BMS
GPRP280L231115R2901 296.00 57.99 41.40 GP-PC200 BMS
GPEV280L230913R2908 283.00 57.25 41.74 GP-RN150 BMS
GPHC280H240321R1001 295.00 57.30 41.34 GP-PC200 BMS
GPEV280H240505R1007 306.00 58.00 42.07 GP-PC200 BMS
GPEV280H240314R1007 300.00 58.00 44.44 Unknown
GPEV280H230616R1022 301.00 57.52 42.65 GP-PC200 BMS
GPEV280H240401R1019 301.00 58.00 42.41 Unknown
Specification of The Battery

Pack SN:GDHC280H240312R1310
Pack Type: 12.8V LiFePO4 Battery
Pack Grade: Standard
BMS Type: JBD200A
Balancer Type: None
Heater: Without Heater
Cell Type: Hithium 280
Cell Grade: HSEV
Cells Connection: 4S1P
Pack Test Result

Full Capacity: 295.00 Ah (3.78 kWh)
Max Charge Voltage: 14.49 V
Min Discharge Voltage: 10.00 V
Charge Test Method
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Method
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Charge/Discharge Curve
(Based on GDHC280H240312R1310 Test Data)

Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) RI1 (mΩ) Self Discharge Thick (mm) Test Date
1 146 0IJCBA0B111111DCL0007923 298.36 3,284.9 0.1702 0.0226 71.69 2023-12-23
2 180 0IJCBA0B471111DCM0000411 298.38 3,284.3 0.1700 0.0221 71.65 2023-12-23
3 197 0IJCBA0B471111DCL0031428 298.53 3,284.7 0.1713 0.0214 71.70 2023-12-23
4 206 0IJCBA0B471111DCL0029831 298.43 3,284.7 0.1704 0.0215 71.76 2023-12-23
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.

Home >>  Battery Pack Information Lookup