SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV314H260316R1011 324.00 58.01 41.46 GP-PC200B BMS
GPGT314L250510R1012 328.00 58.01 41.75 GP-JK200 BMS
GPEV314H260423R1010 332.00 57.62 41.95 GP-PC200B BMS
GPEV314H250606R1004 330.00 57.85 41.91 GP-PC200 BMS
GPEV314H250527R1014 332.00 58.01 42.13 GP-JK200 BMS
GPEV314H251111R1009 324.00 58.01 41.36 GP-PC200B BMS
GPEV314H250424R1012 330.00 57.07 40.42 GP-PC200 BMS
GPHC280H240413R1304 294.00 57.05 40.93 GP-PC200 BMS
GPLS314L260527R1606 321.00 56.31 42.94 GP-JK200 BMS
GPHC280H240604R1301 295.00 57.20 41.79 GP-PC200 BMS
GPHC280H240506R1001 292.00 56.21 42.12 GP-PC200 BMS
GPEV314H250917R1022 330.00 58.00 40.79 GP-PC200 BMS
GPEV314H260525R1009 330.00 57.65 42.11 GP-PC200B BMS
GPGT314L250510R1008 329.00 57.98 42.30 GP-JK200 BMS
GPCN314L260128R1008 325.00 57.86 41.11 GP-PC200B BMS
GPEV314H250507R1002 328.00 57.96 41.61 GP-PC200 BMS
GPEV314H260517R1031 327.00 57.81 42.61 GP-PC200B BMS
GPEV280H240620R1019 304.00 57.99 40.66 GP-PC200 BMS
GPEV314H260521R1006 325.00 57.47 43.06 GP-PC200 BMS
GPHC280H240910R1201 289.00 56.07 42.51 GP-JK200 BMS
Specification of The Battery

Pack SN:GPHC280H250530R1203
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Standard
BMS Type: JK200 BMS
Balancer: Built-in BMS 2A
Heater: With Heater
Cell Type: Hithium 280
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 289.00 Ah (14.80 kWh)
Max Charge Voltage: 57.25 V
Min Discharge Voltage: 45.21 V
Charge Test Steps
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Steps
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Charge/Discharge Curve
(Based on GPHC280H250530R1203 Test Data)

Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) RI1 (mΩ) Self Discharge Thick (mm) Test Date
1 12 0IJCBA08531131D700002867 299.70 3,283.4 0.1713 0.0254 71.61 9598-06-04
2 52 0IJCBA08911131D790005187 299.73 3,283.8 0.1701 0.0209 71.64 6144-06-04
3 61 0IJCBA08481131D8D0000330 299.61 3,282.2 0.1707 0.0254 71.52 1970-01-01
4 71 0IJCBA0C581111D7J0001410 299.35 3,284.9 0.1720 0.0253 71.61 1970-01-01
5 85 0IJCBA0C581111D7G0008915 299.59 3,284.5 0.1724 0.0260 71.59 9622-06-04
6 90 0IJCBA0C581111D7G0008895 299.93 3,284.5 0.1709 0.0261 71.57 9622-06-04
7 99 0IJCBA0C581111D7J0005053 299.53 3,284.1 0.1698 0.0265 71.58 1970-01-01
8 120 0IJCBA0C581111D7H0005412 299.26 3,283.3 0.1716 0.0225 71.61 1970-01-01
9 121 0IJCBA0C581111D7L0002232 299.92 3,282.9 0.1709 0.0222 71.60 7855-06-04
10 132 0IJCBA0D791111D7H0007513 299.89 3,283.6 0.1688 0.0258 71.63 1970-01-01
11 148 0IJCBA0B241111D7H0000973 299.81 3,284.3 0.1672 0.0251 71.62 0823-06-04
12 151 0IJCBA0D791111D7M0005090 299.88 3,280.8 0.1650 0.0259 71.59 1970-01-01
13 178 0IJCBA0C581111D7G0008907 299.46 3,284.4 0.1694 0.0261 71.60 9622-06-04
14 221 0IJCBA0D741111D7Y0001483 299.39 3,280.7 0.1710 0.0211 71.85 1970-01-01
15 222 0IJCBA0C581111D7G0010644 299.99 3,284.5 0.1679 0.0262 71.59 0044-06-04
16 224 0IJCBA0C581111D7G0010017 299.99 3,284.6 0.1681 0.0260 71.61 0247-06-04
Interest in our Products? Submit a Form and Get a Quote Get Quote
Why Max Charge Voltage and Min Discharge Voltage Matter

For LiFePO₄ batteries, Max Charge Voltage and Min Discharge Voltage are not just technical data — they reflect the consistency and balance of every single cell inside the pack.

When all cells reach the charging and discharging limits almost at the same time, it shows that the pack is perfectly matched, with highly uniform voltage and internal resistance. This means better efficiency, higher usable capacity, and a much longer lifespan.

At our factory, every battery pack is tested individually, and its Max Charge Voltage and Min Discharge Voltage results are published on our website for full transparency.

Most manufacturers do not share such detailed data — but we do, because we believe:

-- Real quality can be proven with real numbers

Home >>  Battery Pack Information Lookup