SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPHC280H240413R1401 292.00 56.11 42.61 GP-PC200 BMS
GPHC280H240422R1005 295.00 57.24 40.69 GP-PC200 BMS
GPEV280H231030R1023 302.00 57.45 42.05 GP-PC200 BMS
GPEV280H231220R1029 304.00 58.00 43.00 GP-PC200 BMS
GPEV280H230705R1002 304.00 57.98 41.32 GP-PC200 BMS
GPEV280L230913R2913 285.00 57.53 40.69 GP-PC200 BMS
GPEV280H230616R1006 303.00 57.21 41.48 GP-PC200 BMS
GPRP280L231012R1001 294.00 57.69 40.55 GP-PC200 BMS
GPEV280H240505R1012 301.00 57.99 42.44 GP-PC200 BMS
GPHC280H240506R1016 294.00 57.31 40.95 GP-PC200 BMS
GPEV280H240507R1021 300.00 57.91 42.86 GP-PC200 BMS
GPEV280L230801R2101 287.00 57.69 40.01 GP-PC200 BMS
GPHC280H240422R1201 297.00 57.15 41.47 GP-PC200 BMS
GPEV280H240129R1002 301.00 58.00 43.25 GP-PC200 BMS
GPHC280H240422R1001 295.00 57.38 41.79 GP-JK200 BMS
GPEV280L230523R1009 285.00 56.34 40.70 GP-PC200 BMS
GPHC280H240422R1404 294.00 56.98 40.96 GP-PC200 BMS
GPEV280H240129R1006 300.00 57.99 42.66 GP-PC200 BMS
GPEV280H231019R1019 300.00 57.84 42.61 GP-PC200 BMS
GPEV280H231030R1013 294.00 56.03 43.58 GP-PC200 BMS
Specification of The Battery

Pack SN:GPHC280H240506R1010
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Standard
BMS Type: GP-PC200 BMS
Balancer Type: 4A Bluetooth Active Balancer
Heater: Without Heater
Cell Type: Hithium 280
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 294.00 Ah (15.05 kWh)
Max Charge Voltage: 57.03 V
Min Discharge Voltage: 40.73 V
Charge Test Method
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Method
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Charge/Discharge Curve
(Based on GPHC280H240506R1010 Test Data)

Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) RI1 (mΩ) Self Discharge Thick (mm) Test Date
1 2 0IJCBA0B111111DCK0024646 300.59 3,284.2 0.1730 0.0206 71.64 2023-12-21
2 148 0IJCBA0B111111DCK0030766 300.45 3,284.6 0.1719 0.0207 71.70 2023-12-22
3 155 0IJCBA0B111111DCK0030761 300.19 3,284.2 0.1732 0.0207 71.70 2023-12-22
4 163 0IJCBA0B111111DCL0003658 300.41 3,284.1 0.1723 0.0207 71.65 2023-12-22
5 164 0IJCBA0B471111DCL0023633 300.15 3,283.6 0.1713 0.0205 71.88 2023-12-22
6 254 0IJCBA0B111111DCK0023319 300.08 3,284.1 0.1744 0.0206 71.59 2023-12-21
7 270 0IJCBA0B111111DCK0026646 300.42 3,284.1 0.1721 0.0206 71.70 2023-12-21
8 286 0IJCBA0B111111DCK0026728 300.30 3,284.0 0.1737 0.0207 71.72 2023-12-21
9 299 0IJCBA0B111111DCK0026735 300.41 3,284.3 0.1705 0.0204 71.71 2023-12-21
10 302 0IJCBA0B111111DCK0025183 300.64 3,284.4 0.1698 0.0207 71.72 2023-12-21
11 386 0IJCBA0B111111DCF0024395 300.75 3,284.9 0.1741 0.0205 71.70 2023-12-22
12 446 0IJCBA0B471111DCL0026857 300.21 3,284.5 0.1705 0.0205 71.83 2023-12-22
13 457 0IJCBA0B111111DCL0003911 300.09 3,284.4 0.1738 0.0207 71.62 2023-12-22
14 463 0IJCBA0B111111DCL0003889 300.19 3,284.3 0.1754 0.0208 71.67 2023-12-22
15 492 0IJCBA0B471111DCL0028131 300.57 3,284.8 0.1741 0.0207 71.68 2023-12-22
16 520 0IJCBA0B471111DCL0027402 300.32 3,284.4 0.1705 0.0208 71.68 2023-12-22
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.