Your No.1 Choice for High-Quality Batteries.

Home

Contact Us

Downloads

Reseller Login

Aftersale&Forum

Battery Pack Information Lookup

Get Data of Your Gobel Power Battery
Decode
GP-SR1-PC200 Premium Example: GPEV280H240520R1006
GP-SR1-PC200 Standard Example: GPHC280H240401R1003
GP-SR1-PC200 Standard Example: GPEV280H240927R1001
GP-SR1-PC200 Basic Example: GPCN280L240809R1001
GP-SR1-PC314 Premium Example: GPEV314H240921R1012
GP-SR1-JK314 Standard Example: GPEV314M250109R1001
GP-SR1-JK314 Standard Example: GPGT314L250510R1011
GP-SR3-PC100 Example: GPEV100H240930R1003
GP-LA12-280AH Premium Example: GDEV280H240307R1008
GP-LA12-280AH Standard Example: GDHC280H240312R1401
More Examples
SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV280H240507R1002 302.00 58.00 41.29 GP-PC200 BMS
GPEV100H241022R1020 104.00 57.98 41.43 GP-PC100 BMS
GPEV314H250512R1025 330.00 57.65 42.84 GP-PC200 BMS
GPEV314H250314R1012 333.00 57.60 40.88 GP-PC200 BMS
GPEV280H240710R1007 304.00 57.78 41.52 GP-PC200 BMS
GPEV280H230625R1041 306.00 57.11 41.78 GP-PC200 BMS
GPEV280H250509R1003 309.00 58.01 41.81 GP-PC200 BMS
GPEV280H230625R1033 307.00 57.18 40.66 GP-PC200 BMS
GPGT314L250511R1705 324.00 57.42 41.40 GP-JK200 BMS
GPEV280H240611R1005 304.00 57.99 40.99 GP-PC200 BMS
GPBT314M250307R1001 327.00 56.81 41.60 GP-JK200 BMS
GPEV280H241119R1004 304.00 57.56 41.81 GP-PC200 BMS
GPEV314H250517R1023 332.00 58.01 41.67 GP-PC200 BMS
GPEV280H240105R1012 297.00 58.00 43.50 GP-PC200 BMS
GPEV314H250424R1004 331.00 57.98 42.13 GP-PC200 BMS
GPEV280H231123R1014 299.00 58.00 42.59 GP-PC200 BMS
GPEV314H250329R1003 331.00 57.99 42.26 GP-PC200 BMS
GPEV314H250307R1004 328.00 57.22 41.44 GP-PC200 BMS
GPEV280H231220R1021 295.00 58.00 43.37 GP-PC200 BMS
GPEV314H241231R1009 327.00 57.59 42.07 GP-PC200 BMS
Specification of The Battery

Pack SN:GPEV314H250517R1006
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: GP-PC200 BMS
Balancer: 4A Bluetooth Active Balancer
Heater: Without Heater
Cell Type: EVE 314Ah
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 329.00 Ah (16.84 kWh)
Max Charge Voltage: 58.00 V
Min Discharge Voltage: 41.36 V
Charge Test Steps
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Steps
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Charge/Discharge Curve
(Based on GPEV314H250517R1006 Test Data)

Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) OCV2 (mV) OCV3 (mV) RI1 (mΩ) RI2 (mΩ) RI3 (mΩ) Thick (mm) Test Date
1 46 04QCB43K12701QF2J0743946 333.80 3,268.2 3,266.2 3,297.7 0.1715 0.1734 0.1744 71.40 2025-04-17
2 57 04QCB43K12701QF2J0743348 333.78 3,268.4 3,266.3 3,297.7 0.1751 0.1764 0.1753 71.76 2025-04-17
3 92 04QCB43K12701QF2J0743826 333.75 3,268.6 3,266.5 3,297.6 0.1728 0.1741 0.1740 71.57 2025-04-17
4 116 04QCB43K32701QF2J0697228 333.69 3,268.5 3,266.6 3,297.6 0.1730 0.1755 0.1730 71.37 2025-04-17
5 130 04QCB43K12701QF2H0739709 333.73 3,268.0 3,266.2 3,297.7 0.1752 0.1717 0.1664 71.60 2025-04-17
6 175 04QCB43K12701QF2J0741042 333.77 3,268.6 3,266.6 3,297.8 0.1716 0.1732 0.1732 71.38 2025-04-17
7 196 04QCB43K12701QF2J0743413 333.72 3,268.2 3,266.4 3,297.5 0.1701 0.1691 0.1736 71.37 2025-04-17
8 211 04QCB43K12701QF2J0742357 333.74 3,268.4 3,266.5 3,297.7 0.1740 0.1734 0.1738 71.45 2025-04-17
9 219 04QCB43K32701QF2J0696321 333.75 3,268.3 3,266.4 3,297.7 0.1766 0.1770 0.1767 71.53 2025-04-17
10 222 04QCB43K22701QF2J0500846 333.78 3,268.2 3,266.5 3,297.8 0.1716 0.1725 0.1712 71.38 2025-04-17
11 236 04QCB43K12701QF2J0742593 333.77 3,268.0 3,266.4 3,297.7 0.1707 0.1712 0.1730 71.43 2025-04-17
12 245 04QCB43K22701QF2J0500484 333.75 3,268.0 3,266.2 3,297.6 0.1706 0.1710 0.1724 71.41 2025-04-17
13 254 04QCB43K32701QF2J0697231 333.70 3,268.4 3,266.6 3,297.6 0.1756 0.1757 0.1774 71.66 2025-04-17
14 256 04QCB43K12701QF2J0743532 333.73 3,268.1 3,266.3 3,297.7 0.1727 0.1729 0.1751 71.76 2025-04-17
15 257 04QCB43K22701QF2J0502558 333.75 3,268.2 3,266.4 3,297.7 0.1693 0.1686 0.1643 71.36 2025-04-17
16 339 04QCB43K22701QF2J0501773 333.79 3,268.3 3,266.4 3,297.8 0.1725 0.1731 0.1752 71.50 2025-04-17
Interest in our Products? Submit a Form and Get a Quote Get Quote
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.