Your No.1 Choice for High-Quality Batteries.

Home

Contact Us

Downloads

Reseller Login

Aftersale&Forum

Battery Pack Information Lookup

Get Data of Your Gobel Power Battery
Decode
GP-SR1-PC314 Premium Example: GPEV314H240921R1012
GP-SR1-JK314 Standard Example: GPEV314M250109R1001
GP-SR1-JK314 Standard Example: GPGT314L250510R1011
GP-SR1-JK314 Standard Example: GPBT314M250926R1003
GP-SR1-JK314 Standard Example: GPCN314M250929R1003
GP-SR3-PC100 Example: GPEV100H240930R1003
GP-LA12-280AH Premium Example: GDEV280H240307R1008
GP-LA12-280AH Standard Example: GDHC280H240312R1401
More Examples
SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPRP280L231207R2701 285.00 57.59 41.10 GP-PC200 BMS
GPEV280L230801R2405 289.00 57.41 40.28 GP-PC200 BMS
GPEV280H240814R1015 306.00 57.07 41.43 GP-PC200 BMS
GPEV314H250718R1012 325.00 58.00 41.27 GP-PC200 BMS
GPEV280H240923R1003 306.00 57.60 41.86 GP-PC200 BMS
GPEV314H250418R1006 330.00 57.39 41.25 GP-PC200 BMS
GPEV280H240520R1003 307.00 57.95 41.95 GP-JK200 BMS
GPHC280H240427R1201 295.00 57.45 40.75 GP-PC200 BMS
GPEV280H230802R1002 304.00 57.97 41.44 GP-PC200 BMS
GPEV230H250525R1001 238.00 57.99 40.25 Unknown
GPEV314H250625R1003 325.00 57.96 43.22 GP-PC200 BMS
GPEV280L230913R2927 288.00 57.72 40.37 GP-PC200 BMS
GPEV314H250522R1008 331.00 57.88 41.25 GP-PC200 BMS
GPEV314H250619R1011 325.00 57.93 41.91 GP-PC200 BMS
GPEV314H241226R1003 329.00 57.66 41.18 GP-JK200 BMS
GPEV280H240710R1012 302.00 57.99 42.21 GP-PC200 BMS
GPEV280H240905R1020 306.00 57.45 42.68 GP-RN200 BMS
GPEV314H250606R1009 331.00 57.73 41.74 GP-PC200 BMS
GPEV314H251106R1011 331.00 58.01 41.02 GP-JK200 BMS
GPEV314H250228R1006 329.00 57.52 42.63 GP-PC200 BMS
Specification of The Battery

Pack SN:GPEV280H250407R1008
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: GP-PC200 BMS
Balancer: 4A Bluetooth Active Balancer
Heater: Without Heater
Cell Type: EVE LF280K
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 302.00 Ah (15.46 kWh)
Max Charge Voltage: 57.81 V
Min Discharge Voltage: 41.71 V
Charge Test Steps
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Steps
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Charge/Discharge Curve
(Based on GPEV280H250407R1008 Test Data)

Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) OCV2 (mV) OCV3 (mV) RI1 (mΩ) RI2 (mΩ) RI3 (mΩ) Thick (mm) Test Date
1 1 04QCB76L20003LEBF0005403 307.66 0.0 0.0 3,243.8 0.0000 0.0000 0.1530 71.47 2025-03-03
2 31 04QCB76L20003LEBD0008162 307.53 0.0 0.0 3,245.0 0.0000 0.0000 0.1530 71.47 2025-03-03
3 80 04QCB76L20003LEBE0002306 307.74 0.0 0.0 3,248.0 0.0000 0.0000 0.1520 71.48 2025-03-02
4 82 04QCB76L20003LEBD0011416 307.88 0.0 0.0 3,247.6 0.0000 0.0000 0.1520 71.47 2025-03-02
5 87 04QCB76L20003LEBD0008149 307.96 0.0 0.0 3,245.0 0.0000 0.0000 0.1530 71.50 2025-03-03
6 98 04QCB76L20003LEBE0001358 307.67 0.0 0.0 3,247.8 0.0000 0.0000 0.1530 71.50 2025-03-02
7 99 04QCB76L20003LEBD0011485 307.60 0.0 0.0 3,248.0 0.0000 0.0000 0.1520 71.46 2025-03-02
8 102 04QCB76L20003LEBE0001779 307.57 0.0 0.0 3,247.9 0.0000 0.0000 0.1540 71.50 2025-03-02
9 103 04QCB76L20003LEBE0000009 307.42 0.0 0.0 3,246.7 0.0000 0.0000 0.1540 71.48 2025-03-02
10 108 04QCB76L20003LEBE0000219 307.92 0.0 0.0 3,247.0 0.0000 0.0000 0.1530 71.53 2025-03-02
11 121 04QCB76L20003LEBE0001527 307.47 0.0 0.0 3,247.7 0.0000 0.0000 0.1530 71.49 2025-03-02
12 123 04QCB76L20003LEBD0011325 307.97 0.0 0.0 3,247.9 0.0000 0.0000 0.1530 71.46 2025-03-02
13 129 04QCB76L20003LEBE0001532 307.61 0.0 0.0 3,247.9 0.0000 0.0000 0.1510 71.48 2025-03-02
14 136 04QCB76L20003LEBE0001686 307.87 0.0 0.0 3,247.1 0.0000 0.0000 0.1520 71.47 2025-03-02
15 140 04QCB76L20003LEB40000476 307.40 0.0 0.0 3,244.8 0.0000 0.0000 0.1530 71.49 2025-03-02
16 141 04QCB76L20003LEBE0001530 307.40 0.0 0.0 3,247.8 0.0000 0.0000 0.1510 71.50 2025-03-02
Interest in our Products? Submit a Form and Get a Quote Get Quote
Why Max Charge Voltage and Min Discharge Voltage Matter

For LiFePO₄ batteries, Max Charge Voltage and Min Discharge Voltage are not just technical data — they reflect the consistency and balance of every single cell inside the pack.

When all cells reach the charging and discharging limits almost at the same time, it shows that the pack is perfectly matched, with highly uniform voltage and internal resistance. This means better efficiency, higher usable capacity, and a much longer lifespan.

At our factory, every battery pack is tested individually, and its Max Charge Voltage and Min Discharge Voltage results are published on our website for full transparency.

Most manufacturers do not share such detailed data — but we do, because we believe:

-- Real quality can be proven with real numbers

Home >>  Battery Pack Information Lookup