SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV280H230911R1001 299.00 56.75 42.18 GP-PC200 BMS
GPEV280H240507R1011 301.00 57.99 42.44 GP-PC200 BMS
GPHC280H240422R1202 293.00 56.09 42.08 GP-PC200 BMS
GPEV280H240314R1014 305.00 58.00 41.86 GP-PC200 BMS
GPEV280L230801R2216 288.00 57.19 40.36 GP-PC200 BMS
GPEV280H231220R1011 297.00 57.99 43.33 GP-PC200 BMS
GPEV280H240122R1001 297.00 58.00 41.84 GP-PC200 BMS
GPEV280H240507R1016 302.00 58.00 41.73 GP-PC200 BMS
GPEV280L230801R1504 288.00 57.99 41.34 GP-RN150 BMS
GPEV280H230625R1034 308.00 57.00 40.30 GP-PC200 BMS
GPRP280L231127R2603 285.00 57.86 40.97 GP-PC200 BMS
GPEV280H230625R1021 307.00 57.11 40.97 GP-PC200 BMS
GPHC280H240506R1008 294.00 56.83 41.49 GP-PC200 BMS
GPEV280H240112R1008 300.00 57.99 41.31 GP-PC200 BMS
GPEV306H240514R1005 329.00 57.66 41.78 GP-JK200 BMS
GPEV280L230913R2908 283.00 57.25 41.74 GP-RN150 BMS
GPHC280H240506R2901 294.00 57.28 41.43 GP-PC200 BMS
GPRP280L231012R1308 289.00 57.62 40.04 GP-PC200 BMS
GPEV280H230705R1013 304.00 56.74 41.16 GP-PC200 BMS
GPEV280H230616R1016 304.00 57.44 41.32 GP-PC200 BMS
Specification of The Battery

Pack SN:GPEV280H230625R1028
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: GP-PC200 BMS
Balancer Type: 5A Active Balancer
Heater: With Heater
Cell Type: EVE LF280K
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 306.00 Ah (15.67 kWh)
Max Charge Voltage: 57.71 V
Min Discharge Voltage: 40.66 V
Charge Test Method
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Method
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) OCV2 (mV) OCV3 (mV) RI1 (mΩ) RI2 (mΩ) RI3 (mΩ) Thick (mm) Test Date
1 43 04QCB76G59403JD5H0000605 315.20 2,800.7 2,794.3 3,297.2 0.1577 0.1570 0.1584 71.48 2023-06-08
2 44 04QCB76G55703JD5G0000992 315.20 2,800.8 2,791.8 3,297.4 0.1525 0.1572 0.1565 71.50 2023-06-08
3 248 04QCB76G55703JD5G0001742 315.19 2,799.0 2,790.7 3,297.6 0.1577 0.1559 0.1573 71.64 2023-06-08
4 274 04QCB76G55703JD5G0001737 315.20 2,798.9 2,790.7 3,297.6 0.1577 0.1569 0.1583 71.50 2023-06-08
5 310 04QCB76G55703JD5G0001738 315.21 2,798.2 2,790.1 3,297.6 0.1575 0.1550 0.1574 71.55 2023-06-08
6 335 04QCB76G55703JD5G0003615 315.18 2,811.4 2,803.7 3,297.2 0.1558 0.1553 0.1568 71.48 2023-06-08
7 358 04QCB76G55703JD5G0002785 315.20 2,800.2 2,794.5 3,297.4 0.1589 0.1601 0.1578 71.48 2023-06-08
8 363 04QCB76G59403JD5H0000626 315.16 2,802.1 2,794.1 3,297.1 0.1573 0.1580 0.1580 71.50 2023-06-08
9 367 04QCB76G41203JD5G0002914 315.19 2,805.4 2,797.7 3,297.5 0.1562 0.1530 0.1529 71.46 2023-06-08
10 373 04QCB76G55703JD5G0002082 315.19 2,800.1 2,794.2 3,297.4 0.1517 0.1525 0.1546 71.49 2023-06-08
11 393 04QCB76G55703JD5G0003228 315.18 2,800.7 2,795.2 3,297.6 0.1556 0.1572 0.1552 71.50 2023-06-08
12 439 04QCB76G55503JD5G0004883 315.16 2,801.5 2,791.4 3,297.7 0.1535 0.1525 0.1511 71.61 2023-06-09
13 460 04QCB76G55703JD5G0000784 315.20 2,804.8 2,798.1 3,297.7 0.1515 0.1548 0.1517 71.47 2023-06-09
14 473 04QCB76G55503JD5G0000924 315.16 2,798.1 2,789.3 3,297.8 0.1550 0.1557 0.1517 71.48 2023-06-09
15 483 04QCB76G41103JD5G0005984 315.24 2,804.0 2,795.5 3,297.6 0.1548 0.1544 0.1511 71.57 2023-06-09
16 630 04QCB76G41203JD5G0000894 315.24 2,805.5 2,796.4 3,297.7 0.1514 0.1556 0.1506 71.47 2023-06-09
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.

Home >>  Battery Pack Information Lookup