SN Capacity (Ah) Max Charge Voltage (V) Min Discharge Voltage (V) BMS
GPEV280H231220R1001 293.00 58.00 43.09 GP-PC200 BMS
GPEV280H231204R1004 302.00 57.87 42.30 GP-PC200 BMS
GPEV280L230913R2907 282.00 56.69 41.88 GP-RN150 BMS
GPHC280H240413R2901 293.00 56.39 41.70 GP-PC200 BMS
GPEV280H230705R1026 306.00 57.75 41.29 GP-PC200 BMS
GPHC280H240321R1205 296.00 57.72 40.72 GP-PC200 BMS
GPEV280L230602R1607 302.00 56.35 41.00 GP-PC200 BMS
GPRP280L231012R1302 291.00 57.99 40.00 GP-PC200 BMS
GPEV280L230602R2008 286.00 57.01 40.54 GP-PC200 BMS
GPEV280H240505R1015 306.00 58.00 42.90 GP-PC200 BMS
GPEV280H230911R1006 301.00 56.93 41.40 GP-PC200 BMS
GPEV280L230523R1007 284.00 56.55 41.23 GP-PC200 BMS
GPRP280L231207R3503 284.00 57.99 41.80 GP-PC200 BMS
GPEV280H231227R1002 302.00 58.00 41.30 GP-PC200 BMS
GPEV280L230913R2912 285.00 56.93 41.87 GP-RN150 BMS
GPEV280H240323R1005 294.00 57.36 42.13 GP-PC200 BMS
GPEV280H231019R1027 300.00 57.74 41.52 GP-PC200 BMS
GPRP280L231127R2902 288.00 57.27 42.58 GP-PC200 BMS
GPEV280L230801R2210 289.00 57.95 40.38 GP-PC200 BMS
GPHC280H240506R1206 293.00 57.05 41.27 GP-PC200 BMS
Specification of The Battery

Pack SN:GPEV280H230625R1016
Pack Type: 51.2V LiFePO4 Battery
Pack Grade: Premium
BMS Type: GP-PC200 BMS
Balancer Type: 5A Active Balancer
Heater: Without Heater
Cell Type: EVE LF280K
Cell Grade: HSEV
Cells Connection: 16S1P
Pack Test Result

Full Capacity: 306.00 Ah (15.67 kWh)
Max Charge Voltage: 57.88 V
Min Discharge Voltage: 40.92 V
Charge Test Method
  • Charging at a constant current of 100A, with a maximum charging voltage of 55.5V.
  • Charging at a constant voltage of 55.5V, with a cutoff current of 40A.
  • Charging at a constant current of 40A, with a maximum charging voltage of 58V.
  • Document the maximum charging voltage when the voltage of a single cell reaches 3.65V.
  • * Tested without deliberated active balance procedure.
Discharge Test Method
  • Discharging at a constant current of 100A.
  • Document the minimum discharging voltage when the voltage of a single cell reaches 2.5V.
  • * Please be aware that the charge/discharge curve and capacity of batteries can vary with changing temperatures throughout the seasons. In winter, tested capacity will be relatively lower.
Cells Information

Cell Id QR Capacity (Ah) OCV1 (mV) OCV2 (mV) OCV3 (mV) RI1 (mΩ) RI2 (mΩ) RI3 (mΩ) Thick (mm) Test Date
1 14 04QCB76G42103JD5J0001286 314.53 2,804.3 2,799.6 3,297.4 0.1536 0.1531 0.1551 71.50 2023-06-08
2 76 04QCB76G41203JD5G0000199 314.49 2,802.4 2,793.7 3,297.3 0.1511 0.1535 0.1546 71.47 2023-06-08
3 78 04QCB76G55703JD5G0001962 314.52 2,802.2 2,795.2 3,297.3 0.1550 0.1570 0.1566 71.49 2023-06-08
4 266 04QCB76G59403JD5H0002639 314.53 2,802.8 2,798.1 3,297.4 0.1561 0.1560 0.1580 71.54 2023-06-08
5 270 04QCB76G41203JD5G0001716 314.49 2,799.8 2,791.9 3,297.6 0.1533 0.1517 0.1537 71.44 2023-06-08
6 291 04QCB76G55703JD5G0002122 314.48 2,801.0 2,794.8 3,297.5 0.1534 0.1558 0.1543 71.48 2023-06-08
7 321 04QCB76G59403JD5H0002298 314.50 2,805.0 2,801.3 3,297.5 0.1582 0.1558 0.1579 71.54 2023-06-08
8 337 04QCB76G52503JD5F0003131 314.52 2,798.0 2,793.3 3,297.4 0.1545 0.1567 0.1560 71.83 2023-06-08
9 386 04QCB76G59403JD5H0000723 314.48 2,797.2 2,790.6 3,297.7 0.1536 0.1539 0.1557 71.52 2023-06-08
10 458 04QCB76G41203JD5G0000940 314.52 2,806.8 2,798.4 3,297.7 0.1518 0.1504 0.1494 71.43 2023-06-09
11 500 04QCB76G41103JD5G0005983 314.50 2,802.3 2,793.7 3,297.6 0.1507 0.1516 0.1487 71.58 2023-06-09
12 505 04QCB76G41103JD5F0000660 314.53 2,806.2 2,800.5 3,297.3 0.1551 0.1549 0.1501 71.52 2023-06-09
13 538 04QCB76G69903JD5G0000094 314.48 2,799.9 2,793.1 3,297.6 0.1541 0.1524 0.1574 71.50 2023-06-08
14 547 04QCB76G41103JD5G0009463 314.48 2,805.4 2,797.1 3,297.7 0.1544 0.1522 0.1503 71.42 2023-06-09
15 564 04QCB76G41203JD5H0010120 314.53 2,785.7 2,779.9 3,297.3 0.1507 0.1536 0.1550 71.50 2023-06-08
16 633 04QCB76G55503JD5G0004357 314.50 2,802.6 2,793.2 3,297.8 0.1551 0.1532 0.1524 71.59 2023-06-09
Why Cells Consistency is Important?

Cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery, or indeed any type of battery, refers to the uniformity of the performance and characteristics of the individual cells within the battery.

When a battery is made up of multiple cells, it's important that each cell has the same capacity, internal resistance, self-discharge rate, and other performance characteristics. This is because the overall performance of the battery is only as good as its weakest cell. If one cell has a lower capacity or higher internal resistance, it can reduce the performance of the entire battery, and can even lead to premature failure of the battery.

In a series configuration, the same current flows through all cells. If one cell has a lower capacity, it will discharge faster than the others. Once this cell is fully discharged, the overall battery voltage will drop significantly, even though the other cells still have charge left. This can lead to underutilization of the overall battery capacity.

In a parallel configuration, all cells share the same voltage. If one cell has a higher self-discharge rate, it will drain the other cells to balance its voltage, leading to a faster overall discharge rate.

Moreover, inconsistencies between cells can lead to issues with balancing. Balancing is the process of ensuring all cells in a battery are at the same state of charge. This is typically done by either transferring charge from higher charged cells to lower charged ones (active balancing), or by dissipating excess charge in the higher charged cells (passive balancing). If the cells are inconsistent, it can make balancing more difficult and less effective.

Therefore, cell consistency is crucial for maximizing the performance, longevity, and safety of a battery. This is why Gobel Power puts a lot of effort into cell selection and sorting, to ensure that only cells with similar characteristics are used together in a battery.

Static parameters such as capacities, internal resistances, and voltage levels, though informative, may not provide a comprehensive picture of cell consistency in a LiFePO4 (Lithium Iron Phosphate) battery. A more practical and straightforward method to assess cell consistency involves monitoring the maximum charge voltage when a single cell reaches 3.65V. This is based on the understanding that if the cells exhibit good consistency, the voltage variation across them will be minimal, resulting in a higher overall maximum charge voltage. Therefore, observing the maximum charge voltage when one cell attains 3.65V can serve as a reliable indicator of the battery's cell consistency.

Home >>  Battery Pack Information Lookup